Key benefits

  • excellent reaction to fire: class A2-s1,d0
  • excellent fire resistance: REI classification
  • excellent thermal insulation performance (U-value)
  • very good load-bearing performance as a wall cladding panel
  • CFC- and HCFC-free

Available in

  • effective width: 1000mm and 1170mm
  • nominal thickness: 50mm to 220mm
  • bespoke lengths: 2m to 14m, depending on project requirements

Technical characteristics

Nominal thickness
Thermal transmittance (U-value)
Thermal resistance (R-value)
Fire resistance (R Fire)
Reaction to fire (Classification)
Sound reduction index Rw
Nominal thickness
50
Thermal transmittance (U-value)
0,70
Thermal resistance (R-value)
1,42
Fire resistance (R Fire)
EI 15
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
30 (-1;-3)
Nominal thickness
60
Thermal transmittance (U-value)
0,57
Thermal resistance (R-value)
1,74
Fire resistance (R Fire)
EI 30
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
NPD
Nominal thickness
80
Thermal transmittance (U-value)
0,45
Thermal resistance (R-value)
2,22
Fire resistance (R Fire)
EI 90
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
31 (-1;-3)
Nominal thickness
100
Thermal transmittance (U-value)
0,36
Thermal resistance (R-value)
2,76
Fire resistance (R Fire)
EI 180
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
32 (-2;-4)
Nominal thickness
120
Thermal transmittance (U-value)
0,30
Thermal resistance (R-value)
3,31
Fire resistance (R Fire)
EI 240
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
NPD
Nominal thickness
150
Thermal transmittance (U-value)
0,26
Thermal resistance (R-value)
3,82
Fire resistance (R Fire)
EI 240
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
NPD
Nominal thickness
200
Thermal transmittance (U-value)
0,20
Thermal resistance (R-value)
5,07
Fire resistance (R Fire)
EI 240
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
NPD
Nominal thickness
220
Thermal transmittance (U-value)
0,18
Thermal resistance (R-value)
5,57
Fire resistance (R Fire)
EI 240
Reaction to fire (Classification)
A2 s1 d0
Sound reduction index Rw
34 (-1;-2)

*Panel weight and U-value have been calculated based on:
Core density 100 kg/m3
Thermal conductivity 0.033 W/m.K
Steel facing thickness 0.50/0.50 mm
SP coating
(Standards EN 14509 and EN 10211-2)

*Fire classification in accordance with EN 13501-1 and EN 13501-2
*Sound reduction index measured in accordance with EN ISO 140-3 and classified in accordance with EN ISO 717-1.

Facings

  • Galvanised steel (EN 10346 and EN 10143)

Steel grade: DX51D, S220GD, S250GD and S280GD
Coating: hot-dip galvanised, up to Z275 gr/m² or up to AZ265 gr/m² or up to ZM200 gr/m²
Nominal thickness: up to 1.0 mm
Unpainted

  • Pre-painted galvanised steel (EN 10346, EN 10143 and EN 10169)

Steel grade: DX51D, S220GD, S250GD or S280GD
Coating: hot-dip galvanised, up to Z275 gr/m², up to AZ265 gr/m² or up to ZM200 gr/m²
Nominal thickness: up to 1.0 mm
Paint system: SP, PVC, PVDF or PLASTISOL

  • Stainless steel (EN 10088-1 and EN ISO 9445)

Steel grade: AISI 304 2B or AISI 316L
Nominal thickness: up to 0.90 mm
Unpainted: matt or gloss finish

  • Aluminium (EN 485-2 and EN 485-4)

Aluminium alloys: 1xxx or 3xxx
Temper: H14, H24 or H44
Nominal thickness: up to 1.00 mm
Unpainted

  • Pre-painted aluminium (EN 485-2, EN 485-4 and EN 1396)

Aluminium alloys: 1xxx or 3xxx
Temper: H14, H24 or H44
Nominal thickness: up to 1.00 mm
Paint system: SP or PVDF

Profiling

  • External sheet

Flat
Grooved (Box) 100 (50-50)
Microrib
Smooth or embossed (Embossed)

  • Internal sheet

Flat
Grooved (Box) 83 (39-44)

Stone wool core  (ΕΝ 13162) 

Reaction to fire: A2-s1,d0
Non-combustible; does not produce smoke or flaming droplets/particles during combustion.
Density: 100 kg/m³ and 120 kg/m³
Its mechanical strength makes it suitable for structural applications, as it can withstand external pressures and building loads.
Thermal conductivity (λ): 0.033 W/mK
Its low thermal conductivity provides excellent insulation, reducing heat losses and supporting the building’s energy performance.
Water/vapour permeability: μ = 1
The low water vapour resistance supports low moisture absorption and increased resistance to corrosion and wear, making it suitable for humid environments and harsh weather conditions.
Sound insulation: Thanks to its density, it delivers excellent acoustic performance.
Durability: Retains its properties without deterioration or breakdown over time.
Environmental performance: Biosoluble
Free from substances hazardous to health, recyclable, and manufactured in line with environmental standards.

Available Options

Simple Polyester

Nominal coating thickness: <20μm ± 5μm
Surface texture: smooth
The most widely used and cost-effective coating option. Suitable for external and internal surfaces and typically used for building applications inland (1,000 metres from the coastline) in normal environmental conditions (non-corrosive atmospheres, with or without low air pollution). Provides adequate protection (RC3) and long-term aesthetic performance.

Durable PVC Plastisol

Nominal coating thickness: 200μm
Surface texture: orange peel
A “self-healing” coating with the ability to recover from minor damage. Known for excellent durability and ideal for demanding environments.

High Hygiene req PVC

Nominal coating thickness: 120μm
Surface texture: smooth
Colour: white
A “foodsafe” coating offering excellent antibacterial protection. Suitable for projects with high hygiene requirements, including applications where the surface may come into contact with food.

High req PVDF

Nominal coating thickness: 50μm
Ideal for high-spec architectural projects where aesthetics are a priority. Offers high wear resistance and long-term colour retention, even after prolonged UV exposure and adverse weather. Classified as s1 for reaction to fire (low smoke production), making it suitable for building applications with elevated fire-safety requirements.

Coating colour options

A wide variety of colours is available:

RAL 1013
RAL 1014
RAL 1015
RAL 1023
RAL 2008
RAL 2013
DB 302
RAL 3005
RAL 3009
RAL 3011
RAL 3020
RAL 5005
RAL 5010
RAL 5014
RAL 5015
RAL 5024
RAL 6005
RAL 6011
RAL 6017
RAL 6021
RAL 7004
RAL 7015
RAL 7016
RAL 7023
RAL 7030
RAL 7035
RAL 7036
RAL 7037
RAL 7040
RAL 7042
RAL 7044
RAL 7045
RAL 8004
RAL 8014
RAL 8017
RAL 8019
RAL 9002
RAL 9005
RAL 9006
RAL 9007
RAL 9010

For more colours, contact us.

They are fixed to the supporting structure using the standard exposed-fix method.
They can be installed either vertically or horizontally.
For horizontal installation, the use of a top hat is recommended to cover the vertical joint.
Sealing materials must be used on both horizontal and vertical joints.

The panel joint design, combined with sealing materials, achieves:

  • Minimisation of thermal bridging
  • Prevention of air and moisture ingress
  • Reduced installation time
  • Limited need for additional accessories
If you haven't found the ideal product for you, we are here to help!

Coating colors

Wide variety of colors available. For more colors, please contact us.
RAL 1013
RAL 1014
RAL 1015
RAL 1023
RAL 2008
RAL 2013
DB 302
RAL 3005
RAL 3009
RAL 3011
RAL 3020
RAL 5005
RAL 5010
RAL 5014
RAL 5015
RAL 5024
RAL 6005
RAL 6011
RAL 6017
RAL 6021
RAL 7004
RAL 7015
RAL 7016
RAL 7023
RAL 7030
RAL 7035
RAL 7036
RAL 7037
RAL 7040
RAL 7042
RAL 7044
RAL 7045
RAL 8004
RAL 8014
RAL 8017
RAL 8019
RAL 9002
RAL 9005
RAL 9006
RAL 9007
RAL 9010