ThermaBarr COV Slate

ThermaBarr COV Slate are self-supporting insulated roof panels with an external steel facing in a slate tile profile and a polyurethane (PUR) foam core, suitable for roofing any type of building.

Overview
Overview DescriptionAvailable OptionsRelated files
Choose Color

Key benefits

  • excellent thermal insulation performance, U-value
  • very good load-bearing capacity as a roof panel
  • CFC- and HCFC-free

Available in

  • effective cover width 1,000 mm
  • nominal thickness from 40 mm to 120 mm
  • bespoke lengths from 2 m to 14 m, depending on project requirements

Technical characteristics

Nominal thickness
Thermal transmittance (U Value)
Thermal resistance (R Value)
Fire resistance rating (R Fire)
Reaction to fire class (Classification)
Sound insulation index Rw
Nominal thickness
40
Thermal transmittance (U Value)
0,57
Thermal resistance (R Value)
1,74
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD
Nominal thickness
50
Thermal transmittance (U Value)
0,45
Thermal resistance (R Value)
2,21
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD
Nominal thickness
60
Thermal transmittance (U Value)
0,37
Thermal resistance (R Value)
2,69
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD
Nominal thickness
80
Thermal transmittance (U Value)
0,29
Thermal resistance (R Value)
3,48
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD
Nominal thickness
100
Thermal transmittance (U Value)
0,23
Thermal resistance (R Value)
4,38
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD
Nominal thickness
120
Thermal transmittance (U Value)
0,19
Thermal resistance (R Value)
5,28
Fire resistance rating (R Fire)
NPD
Reaction to fire class (Classification)
NPD
Sound insulation index Rw
NPD

*Panel weight and thermal transmittance were calculated taking into account:
Core density 40 kg/m3
Thermal conductivity 0.023 W/m.K
Steel sheet thickness 0.50/0.50 mm
Coating SP
(Standards EN 14509 and EN 10211-2)

Facings

  • Hot-dip galvanised steel (EN 10346 and EN 10143)

Steel grade: DX51D, S220GD, S250GD and S280GD
Coating: hot-dip galvanising, up to Z275 g/m² or up to AZ265 g/m² or up to ZM200 g/m²
Nominal thickness: up to 1.0 mm
Without colour coating

  • Pre-painted hot-dip galvanised steel (EN 10346, EN 10143 and EN 10169)

Steel grade: DX51D, S220GD, S250GD or S280GD
Coating: hot-dip galvanising, up to Z275 g/m², up to AZ265 g/m² or up to ZM200 g/m²
Nominal thickness: up to 1.0 mm
Colour coating: SP, PVC, PVDF or PLASTISOL

  • Stainless steel (EN 10088-1 and EN ISO 9445)

Steel grade: AISI 304 2B or AISI 316L
Nominal thickness: up to 0.90 mm
Without colour coating: matt or gloss finish

  • Aluminium (EN 485-2 and EN 485-4)

Aluminium alloys: 1xxx or 3xxx
Temper: H14, H24 or H44
Nominal thickness: up to 1.00 mm
Without colour coating

  • Pre-painted aluminium (EN 485-2, EN 485-4 and EN 1396)

Aluminium alloys: 1xxx or 3xxx
Temper: H14, H24 or H44
Nominal thickness: up to 1.00 mm
Colour coating: SP or PVDF

Configuration

  • Outer facing

Slate tile profile, element size 200 x 125 mm
Plain or embossed (Embossed)

  • Inner facing

Flat
Mini Box 51 ribbing (25.5-25.5)
Box 100 ribbing (50-50)
Plain or embossed (Embossed)

– Polyurethane (PUR) foam core (EN 13165)

Category: F
Density: 35 to 42 kg/m³
Its mechanical strength makes it perfect for structural applications, capable of supporting building loads. Being lightweight, it ensures easy and fast panel installation.
Thermal conductivity (λ): 0.021 to 0.023 W/mK
The low thermal conductivity ensures superior insulation, minimizing energy losses and enhancing the overall energy efficiency of structures.
Closed-cell structure: 90%
Its high closed-cell structure guarantees minimal water absorption and superior durability against corrosion and decay, making it perfect for wet climates or extreme weather environments.
Sound insulation: due to its density, it also provides good acoustic performance.
Service life: 30 years
Environmental profile: CFC- and HCFC-free
Contains no substances hazardous to health and is manufactured in line with environmental standards.

 

Available Options

Simple Polyester

Nominal coating thickness: 25 μm ± 5 μm
The most widely used and cost-effective coating option for profiled sheets. Suitable for both external and internal surfaces and typically used for building projects in mainland environments under normal conditions (i.e. non-corrosive atmospheres with low air pollution). Provides adequate protection in external environmental conditions (RC3) and long-term aesthetic performance.

Durable PVC Plastisol

Nominal coating thickness: 200 μm
Known for outstanding durability and ideal for high-demand environments. Offers high resistance to wear and long-term colour retention, even after prolonged exposure to UV radiation and adverse weather conditions. Provides adequate protection in external environmental conditions (RC5) and long-term aesthetic performance.

High Hygiene PVC

Nominal coating thickness: 120 μm
A “foodsafe” coating category, offering excellent antibacterial protection. Suitable for indoor constructions that require high hygiene standards, making it ideal for applications where the surface may come into contact with food.

High req PVDF

Nominal coating thickness: 50 μm
Ideal for high-requirement architectural projects where aesthetics are a priority. Offers high resistance to wear and long-term colour retention, even after prolonged exposure to UV radiation and adverse weather conditions. Provides adequate protection in external environmental conditions (RC4) and long-term aesthetic performance.

Coating colour options

A wide range of colours is available:

RAL 1013
RAL 1014
RAL 1015
RAL 1023
RAL 2008
RAL 2013
DB 302
RAL 3005
RAL 3009
RAL 3011
RAL 3020
RAL 5005
RAL 5010
RAL 5014
RAL 5015
RAL 5024
RAL 6005
RAL 6011
RAL 6017
RAL 6021
RAL 7004
RAL 7015
RAL 7016
RAL 7023
RAL 7030
RAL 7035
RAL 7036
RAL 7037
RAL 7040
RAL 7042
RAL 7044
RAL 7045
RAL 8004
RAL 8014
RAL 8017
RAL 8019
RAL 9002
RAL 9005
RAL 9006
RAL 9007
RAL 9010

For more colours, contact us.

They are fixed to the supporting structure using the standard method of visible fixing.
Designed for roofs with a minimum slope of 30%.
Horizontal installation is recommended.
End-lapping (overlap) is not recommended.
Sealing materials must be used at horizontal and vertical joints.

The panel joint design, combined with sealing materials, helps achieve:

  • Minimisation of thermal bridges
  • Prevention of air and moisture ingress
  • Reduced installation time
  • Limited need for additional accessories

Related files

If you haven't found the ideal product for you, we are here to help!

Coating colors

Wide variety of colors available. For more colors, please contact us.
RAL 1013
RAL 1014
RAL 1015
RAL 1023
RAL 2008
RAL 2013
DB 302
RAL 3005
RAL 3009
RAL 3011
RAL 3020
RAL 5005
RAL 5010
RAL 5014
RAL 5015
RAL 5024
RAL 6005
RAL 6011
RAL 6017
RAL 6021
RAL 7004
RAL 7015
RAL 7016
RAL 7023
RAL 7030
RAL 7035
RAL 7036
RAL 7037
RAL 7040
RAL 7042
RAL 7044
RAL 7045
RAL 8004
RAL 8014
RAL 8017
RAL 8019
RAL 9002
RAL 9005
RAL 9006
RAL 9007
RAL 9010